YG125-30A Maintenance Manual Overview
4
8.
In case the fuse is blown, check for the causes and,
after being repaired, replace corresponding fuse as
per the specified capacity.
9.
The caps must be securely put on the terminals
after the operation is complete
10. While disassembling a connector joints with lock,
release the lock before proceeding with operation.
While disassembling a connector joints, hold the
connector body without pulling the wire harness.
Before connecting the connector, the terminals shall be
free from breaking or bending. Make sure the terminals
are not too long or are falling off.
The connector shall be fully inserted in place.
For a connector with lock, confirm whether the lock is
completely fixed.
Make sure the harness is not falling off
Make sure the plastic jacket of the connector is securely
covering the connector without scaling off.
11. Before connecting a connector, make sure the
sleeve is not broken and the opening of the
intermediate terminal is not too large
The joint shall be fully inserted in place.
Make sure the plastic jacket is housing the terminal
completely. The opening of the plastic jacket shall not
face up.
12. The harness fixing strap shall firmly button the
specified position on the frame.
Confirm capacity!
Crackle