YG125-25 Maintenance Manual Frame and exhaust system
Remove the two nut, remove the seat.
Remove the left/right side cover assembly. Handle it
carefully in order to prevent scratching the exterior
decorating surface.
Remove the 2 connecting bolts in the headlamp
bracket.
Remove the 2 connecting screw in the front face of
the motorcycle.
Pull off the headlamp patch plug to remove the
headlamp.
Pull off the left/ right turn lamp connecting wire from
the headlamp bracket.
Remove the meter assembly (total of 2 connecting
bolts).
To mount the coverings, headlamp and meter:
The installation of the coverings, headlamp and meter is
in the reverse order of removal. During installation, do not
scratch the coverings or damage the bulb.
Notice
During removal and installation, do not scratch the
outer surface of coverings or break the buckle
mortise.
Connecting bolt
Connecting screw
Right turn lamp connecting
wire
Left turn lamp connecting wire
Meter assembly