12
8. TOUBLE SHOOTING
Manual Dispenser Part
Failure
Reason analysis
Solution
Motor doesn't work 1. Power
wire
is
not
connected.
2. Fuse wire is burn out.
3. Long time no stirring, so
colorant subsides.
4. Electrical
terminal
get
loose.
5. Motor is damaged.
1. Inspect the power wire and plug.
2. Change fuse wire.
3. Manually stir the colorant subsides, and then
turn on power to stir again.
4. Open the dispenser case and make the electric
terminal tight.
5. Change new motor.
One
or
more
canisters don't stir
1. The crankshaft of canisters
is not inserted into the driving
table plastic hole.
2. Canisters
with
motor:
electric wire plug get loose or
motor is damaged.
1. Remove the screws that connect the canister
with turntable, reinsert the crankshaft into the
plastic holes of driving table.
2. Plug the power wire to the circuit board socket
tightly, or change new motor.
The gauge cannot
be locked to the
needed reticle
1. The connecting pin on
needle sheath breaks off.
1. Use cross crew driver to remove the two screws
beside buttons, and replace with spare needle and
needle sheath. Fasten the screws to connect the
needle sheath with buttons.
There is colorant
on the gauges
1. Pump plunger patch is
damaged.
1. Change new plunger patch.
colorant cannot run
out
during
dispensing.
1. The valve is not opened
when pressing the handle or
valve is not fully opened.
2. The canister nozzle is
blocked.
1. Turn the valve handle counterclockwise to
maximum position and slowing press down;
2. Turn the valve handle counterclockwise; use
toothpick to clean blocked nozzle, or take off the
nozzle and clean it. After installation, do evacuation
before operation.