7.9.5 Range: Read SmartCard
Select among the 3 SmartCard Read options:
Soft Read Enable
When your SmartCard is inserted, VIP
digital
will not accept a preset until one of the Preset Recall
buttons is pressed.
Radical Read Enable
When the SmartCard is inserted, VIP
digital
will accept the preset immediately. The preset number (1,
2 or 3) active prior to insertion will be accepted.
Disable
The data of an inserted SmartCard is ignored.
7.9.6 Range:
Write
SmartCard
Write enabled
Presets can be saved to the SmartCard (
Save to SmartCard
command/button enabled in the
VIP
remote
software)
Write disabled
Presets cannot be saved to the SmartCard (
Save to SmartCard
command/button disabled in the
VIP
remote
software.)
7.9.7 Range: Meter Default
Input Level
After an activation the Level Indicator will show the input level.
Output Level
After an activation the Level Indicator will show the output level.
Note: The Level Indicator shows the selections, using LEDs. The Level Indicator can be switched off
during operation at any time, using the
Meter Mode
menu item in the Enter menu of your VIP
digital
.
The Enter menu allows also switching between Input Level and Output Level.
Note: A Meter Mode
setting performed on your VIP
digital
is stored in a cap-buffered RAM for approx. 24
hrs. after the unit has been switched off. After this time VIP
digital
will return to the selection set in
VIP
con
.
7.9.8 Range: Enter Button
Checkbox:
Function Disabled, No Access to Menu
Click on this checkbox to disable the Enter button.
Now, only the 3 internal presets or your
SmartCard
presets can be selected on VIP
digital
.
All other controls are disabled.
VIP
digital
Manual 4.0 Yellowtec 2004 Rev. 26.07.2004