A.17 V/f Pattern Default Values
The following tables show the V/f pattern setting default values depending on the control mode (A1-02) and the V/f pattern
selection (E1-03 in V/f Control).
Table A.4 E1-03 V/f Pattern Settings for Drive Capacity: 5A0003 to 5A0009
No.
Unit
V/f Control
E1-03
-
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
E1-04
Hz
50.0
60.0
60.0
72.0
50.0
50.0
60.0
60.0
50.0
50.0
60.0
60.0
90.0
120.0
180.0
60.0
E1-05
V
575.0
575.0
575.0
575.0
575.0
575.0
575.0
575.0
575.0
575.0
575.0
575.0
575.0
575.0
575.0
575.0
E1-06
Hz
50.0
60.0
50.0
60.0
50.0
50.0
60.0
60.0
50.0
50.0
60.0
60.0
60.0
60.0
60.0
60.0
E1-07
Hz
2.5
3.0
3.0
3.0
25.0
25.0
30.0
30.0
2.5
2.5
3.0
3.0
3.0
3.0
3.0
3.0
E1-08
V
43.1
43.1
43.1
43.1
100.6
143.8
100.6
143.8
54.6
69.0
54.6
69.0
43.1
43.1
43.1
43.1
E1-09
Hz
1.3
1.5
1.5
1.5
1.3
1.3
1.5
1.5
1.3
1.3
1.5
1.5
1.5
1.5
1.5
1.5
E1-10
V
25.9
25.9
25.9
25.9
23.0
25.9
23.0
25.9
31.6
37.4
31.6
43.1
25.9
25.9
25.9
25.9
<1> This value determines the default values for E1-04 through E1-10 (E3-04 through E3-10 for motor 2).
Table A.5 E1-03 V/f Pattern Settings for Drive Capacity: 5A0011 to 5A0077
No.
Unit
V/f Control
E1-03
-
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
E1-04
Hz
50.0
60.0
60.0
72.0
50.0
50.0
60.0
60.0
50.0
50.0
60.0
60.0
90.0
120.0
180.0
60.0
E1-05
V
575.0
575.0
575.0
575.0
575.0
575.0
575.0
575.0
575.0
575.0
575.0
575.0
575.0
575.0
575.0
575.0
E1-06
Hz
50.0
60.0
50.0
60.0
50.0
50.0
60.0
60.0
50.0
50.0
60.0
60.0
60.0
60.0
60.0
60.0
E1-07
Hz
2.5
3.0
3.0
3.0
25.0
25.0
30.0
30.0
2.5
2.5
3.0
3.0
3.0
3.0
3.0
3.0
E1-08
V
40.3
40.3
40.3
40.3
100.6
143.8
100.6
143.8
51.8
67.0
51.8
67.0
40.3
40.3
40.3
40.3
E1-09
Hz
1.3
1.5
1.5
1.5
1.3
1.3
1.5
1.5
1.3
1.3
1.5
1.5
1.5
1.5
1.5
1.5
E1-10
V
20.1
20.1
20.1
20.1
17.3
20.1
17.3
20.1
25.9
31.6
25.9
37.4
20.1
20.1
20.1
20.1
<1> This value determines the default values for E1-04 through E1-10 (E3-04 through E3-10 for motor 2).
Table A.6 E1-03 V/f Pattern Settings for Drive Capacity: 5A0099 to 5A0242
No.
Unit
V/f Control
E1-03
-
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
E1-04
Hz
50.0
60.0
60.0
72.0
50.0
50.0
60.0
60.0
50.0
50.0
60.0
60.0
90.0
120.0
180.0
60.0
E1-05
V
575.0
575.0
575.0
575.0
575.0
575.0
575.0
575.0
575.0
575.0
575.0
575.0
575.0
575.0
575.0
575.0
E1-06
Hz
50.0
60.0
50.0
60.0
50.0
50.0
60.0
60.0
50.0
50.0
60.0
60.0
60.0
60.0
60.0
60.0
E1-07
Hz
2.5
3.0
3.0
3.0
25.0
25.0
30.0
30.0
2.5
2.5
3.0
3.0
3.0
3.0
3.0
3.0
E1-08
V
34.5
34.5
34.5
34.5
100.6
143.8
100.6
50.0
43.1
57.5
43.1
57.5
34.5
34.5
34.5
34.5
E1-09
Hz
1.3
1.5
1.5
1.5
1.3
1.3
1.5
1.5
1.3
1.3
1.5
1.5
1.5
1.5
1.5
1.5
E1-10
V
17.3
17.3
17.3
17.3
14.4
17.3
14.4
17.3
20.1
25.9
20.1
31.6
17.3
17.3
17.3
17.3
<1> This value determines the default values for E1-04 through E1-10 (E3-04 through E3-10 for motor 2).
A.17 V/f Pattern Default Values
240