Installation and Operation Guide SOLECTRIA XGI 1000
DOCR-070733-F (2/22/2021)
Page 76 of 78
Options
Wiring Box Configurations
The Wire Box comes in several versions. Each version can be ordered in Combined Mode or Independent Mode.
Table 12-1 AC Connection Specifications
WIRE
MATERIAL
STANDARD WIRING BOX
LARGE AC TERMINAL (-L) WIRING
BOX
AC OUTPUT (L1, L2, L3)
CONDUCTORS
Copper
Aluminum
3 to 1/0 AWG (26.7 to 50 mm
2
)
1 to 1/0 AWG (42.4 to 50 mm
2
)
3 to 3/0 AWG (26.7 to 85 mm
2
)
1 to 3/0 AWG (42.4 to 85 mm
2
)
NEUTRAL (NOT A CURRENT
CARRYING CONDUCTOR: CAN
BE SIZED EQUAL TO OR LARGER
THAN THE EGC.)
Copper
Aluminum
8 to 4 AWG (8.4 to 21.2 mm
2
)
6 to 4 AWG (13.3 to 21.2 mm
2
)
6 to 1/0 AWG (13.3 to 50 mm
2
)
6 to 1/0 AWG (13.3 to 50 mm
2
)
EQUIPMENT GROUNDING
CONDUCTOR (EGC)
Copper
Aluminum
8 to 4 AWG (8.4 to 21.2 mm
2
)
6 to 4 AWG (13.3 to 21.2 mm
2
)
6 to 1/0 AWG (13.3 to 50 mm
2
)
6 to 1/0 AWG (13.3 to 50 mm
2
)
Standard Configuration
The Standard Wiring Box is shown in Figure 12-1. See Table 12-1 for allowed AC conductor sizes.
Figure 12-1 Standard Wiring Box