Installation and Operation Guide SOLECTRIA XGI 1000
DOCR-070733-F (2/22/2021)
Page 47 of 78
Port Forwarding, DAS Configuration
The External Access IP and respective Port settings must be configured on the third-party monitoring platform or DAS.
This will allow the DAS to query the desired inverter properly.
Static Routing
To implement Static Routing the XGI Gateway Inverter(s) will need to be configured and a static routing rule will need to
be added to the LAN.
Once implemented, inverters can easily be addressed as an Endpoint Device by a DAS or other external device using the
Inverter Cluster IP address and port 502, for example: 10.78.125.31:502. Inverter Cluster IPs can be configured; see
Section 3.5.8.
Static Routing, Configuring the Gateway Inverter
To configure Static Routing first Enable External Modbus Access by selecting the check box using the GUI of the desired
Gateway Inverter.
By default the Gateway Inverter will detect and recommend an IP/Subnet from which external devices are allowed
through the Inverter Gateway Firewall. For security purposes the user is encouraged to enter the most restrictive value,
with preference given to the specific IP address of the external device (DAS). Up to two IP/Subnet pairs can be entered
on each gateway.