44
YASKAWA
SIEP C730600 86F MECHATROLINK-II Technical Manual
This option displays the CE mark based on the EMC guidelines.
EMC Guidelines: 2014/30/EU
Drives used in combination with this option and devices used in combination with the drive must also be CE
certified and display the CE mark.
When using drives displaying the CE mark in combination with other devices, it is ultimately the responsibility of
the user to ensure compliance with CE standards. Verify that conditions meet European standards after setting up
the device.
◆
EMC Guidelines Compliance
This option is tested according to European standards EN 61800-3:2004/A1:2012 and complies with EMC
guidelines. The CE marking is declared based on the harmonized standards.
■
EMC Guidelines Installation Conditions
Verify the following installation conditions to ensure that other devices and machinery used in combination with
this option and drives also comply with EMC guidelines:
1.
Use dedicated shield cable for the option and external device (encoder, I/O device, master), or run the
wiring through a metal conduit.
2.
Keep wiring as short as possible and ground the largest possible surface area of the shield to the metal
panel as specified by
and
.
Figure 10.2 Option Installation for CE Compliance: 1000-Series, GA700, GA800, CR700, CH700
Figure 10.3 Option Installation for CE Compliance with GA500
3.
Ground the largest possible surface area of the shield to the metal panel.