5 Installation Procedure
YASKAWA ELECTRIC
SIEP YEACOM 01A V1000 Option EtherNet/IP Technical Manual
15
Note:
The four different ground wires packaged with the EtherNet/IP Option connect the unit to different drive models. Select the
proper ground wire from the EtherNet/IP Option kit depending on drive size.
Refer to Ground Wire Selection on page 15
Figure 6
Figure 7 Ground Wire
Table 7 Ground Wire Selection
A – Option unit connection: screw size =
M3
B – Drive-side connection: screw size =
M3.5 to M6
Ground Wire Length
(mm/in)
Drive Model
CIMR-VU
Single-Phase
200 V Class
Three-Phase
200 V Class
Three-Phase
400 V Class
150/5.9
BA0001
BA0002
BA0003
2A0001
2A0002
2A0004
2A0006
-
200/7.9
BA0006
BA0010
BA0012
BA0018
2A0010
2A0012
2A0020
4A0001
4A0002
4A0004
4A0005
4A0007
4A0009
4A0011
250/9.8
-
2A0030
2A0040
4A0018
4A0023
400/15.7
-
2A0056
2A0069
4A0031
4A0038
A
B