![YASKAWA PROFINET V1000 Quick Start Manual Download Page 164](http://html2.mh-extra.com/html/yaskawa/profinet-v1000/profinet-v1000_quick-start-manual_3282778164.webp)
Item
Specification
Environment
Storage/Installation Area
Indoors
Ambient Temperature
IP20/NEMA Type 1 enclosure: -10 °C to +40 °C
IP20/IP00 Open-Chassis enclosure: -10 °C to +50 °C
Finless Type: IP20/IP00 enclosure: -10 °C to +50 °C
NEMA Type 4X/IP66 enclosure: -10 °C to +40 °C
Humidity
95% RH or less with no condensation
Storage Temperature
-20 to +60 °C allowed for short-term transport of the product
Altitude
Up to 1000 meters without derating; up to 3000 meters with output
current and voltage derating.
Shock, Impact
10 to 20 Hz: 9.8 m/s
2
20 to 55 Hz: 5.9 m/s
2
Surrounding Area
Install the drive in an area free from:
• oil mist and dust
• metal shavings, oil, water or other foreign materials
• radioactive materials
• combustible materials
• harmful gases and liquids
• excessive vibration
• chlorides
• direct sunlight
Orientation
Install the drive vertically to maintain maximum cooling effects
Standards
• UL508C
• EN61800-3, EN61800-5-1
• ISO13849-1 Cat.3 PLd, IEC61508 SIL2
Time from input open to drive output stop is less than 1 ms.
Protective Enclosure
IP20/Open-Chassis or IP00/Open-Chassis
IP20/NEMA Type 1
Cooling Method
CIMR-V
o
BA0001 to 0006: self-cooled
CIMR-V
o
BA0010 to 0018: cooling fan
CIMR-V
o
2A0001 to 0004: self-cooled
CIMR-V
o
2A0006 to 0069: cooling fan
CIMR-V
o
4A0001 to 0004: self-cooled
CIMR-V
o
4A0005 to 0038: cooling fan
<1>
Speed control accuracy varies somewhat according to the type of motor and drive settings.
<2>
<3>
<4>
<5>
Parameter settings allow up to 150 V.
A.4 Drive Specifications
164
YASKAWA ELECTRIC TOEP C710606 47A YASKAWA AC Drive – V1000 Quick Start Guide