Drive Model
Normal Duty
Rated Amps (A)
Heatsink Loss (W)
Interior Unit Loss (W)
Total Loss (W)
4A0414
414
3443
1295
4738
4A0515
515
4850
1668
6518
4A0675
675
4861
2037
6898
4A0930
930
8476
2952
11428
4A1200
1200
8572
3612
12184
<1> Value assumes the carrier frequency is 2 kHz (C6-02 = 1, 7, 8, 9, or A).
Table A.12 Watt Loss Three-Phase 600 V Class Three-Phase Models
Drive Model
Normal Duty
Rated Amps (A)
Heatsink Loss (W)
Interior Unit Loss (W)
Total Loss (W)
5A0003
2.7
21.5
23.3
44.8
5A0004
3.9
27.5
33.6
61.1
5A0006
6.1
28.1
43.7
71.8
5A0009
9.0
43.4
68.9
112.3
5A0011
11
56.1
88.0
144.0
5A0017
17
96.6
146.7
243.2
5A0022
22
99.4
178.3
277.7
5A0027
27
132.1
227.2
359.3
5A0032
32
141.6
279.9
421.5
5A0041
41
330.8
136.2
467.0
5A0052
52
427.8
166.2
594.0
5A0062
62
791.2
279.0
1070.2
5A0077
77
959.1
329.4
1288.6
5A0099
99
1253.2
411.7
1664.9
5A0125
125
1641
537
2178
5A0145
145
1860
603
2463
5A0192
192
2420
769
3189
5A0242
242
3100
1131
4231
<1> Value assumes the carrier frequency is 2 kHz (C6-02 = 1, 7, 8, 9, or A).
A.3 Drive Watt Loss Data