17-2
HW0480311
HW0480311
For the Robot Controller: XRC
Parameter No.
Item
Set
Value
Remarks
S2C283
Arc monitoring function: Magnification of current
conversion
200
For welder 1
S2C284
Arc monitoring function: Current offset
0
For welder 1
S2C285
Arc monitoring function: Magnification of voltage
conversion
200
For welder 1
S2C286
Arc monitoring function: Voltage offset
0
For welder 1
S2C287
Arc monitoring function: Magnification of current
conversion
200
For welder 2
S2C288
Arc monitoring function: Current offset
0
For welder 2
S2C289
Arc monitoring function: Magnification of voltage
conversion
200
For welder 2
S2C290
Arc monitoring function: Voltage offset
0
For welder 2
S2C291
Arc monitoring function: Magnification of current
conversion
200
For welder 3
S2C292
Arc monitoring function: Current offset
0
For welder 3
S2C293
Arc monitoring function: Magnification of voltage
conversion
200
For welder 3
S2C294
Arc monitoring function: Voltage offset
0
For welder 3
For details on the arc monitoring function, see "YASNAC XRC INSTRUCTIONS FOR ARC
MONITORING FUNCTION" (Manual No. HW0480429).
SUPPLE
-MENT
119/129