17-1
HW0480311
HW0480311
17
Setting of Arc Monitoring Function
For using the arc monitoring function on the robot side, the setting of parameters for the robot
controller as shown below is required.
For the Robot Controller: NX
Parameters to be set are different according to the type of robot controller.
Parameter No.
Item
Set
Value
Remarks
S2C355
Arc monitoring function: Magnification of current
conversion
200
For welder 1
S2C356
Arc monitoring function: Current offset
0
For welder 1
S2C357
Arc monitoring function: Magnification of voltage
conversion
200
For welder 1
S2C358
Arc monitoring function: Voltage offset
0
For welder 1
S2C359
Arc monitoring function: Magnification of current
conversion
200
For welder 2
S2C360
Arc monitoring function: Current offset
0
For welder 2
S2C361
Arc monitoring function: Magnification of voltage
conversion
200
For welder 2
S2C362
Arc monitoring function: Voltage offset
0
For welder 2
S2C363
Arc monitoring function: Magnification of current
conversion
200
For welder 3
S2C364
Arc monitoring function: Current offset
0
For welder 3
S2C365
Arc monitoring function: Magnification of voltage
conversion
200
For welder 3
S2C366
Arc monitoring function: Voltage offset
0
For welder 3
S2C367
Arc monitoring function: Magnification of current
conversion
200
For welder 4
S2C368
Arc monitoring function: Current offset
0
For welder 4
S2C369
Arc monitoring function: Magnification of voltage
conversion
200
For welder 4
S2C370
Arc monitoring function: Voltage offset
0
For welder 4
NOTE
118/129