4.1 Explanation of Welding Source Panel
4-2
HW0480311
HW0480311
The following table explains the display of the meters
c
,
d
,
e
, and
f
.
The content of the display differs according to the status as follows:
Display Lamps
Status
c
Welding Volt-
age Indicator
d
Welding Cur-
rent Indicator
e
Wire Feeding
Speed Indicator
f
Welding Type
Indicator
During
standb
y
When
Parameter
C32=0,
Displays
Setting
Conditions.
Displays the set
welding voltage
value (V).
Displays the set
welding current
value (A).
Displays the feed-
ing amount (m/
min) of the set
welding current
value.
Displays the weld-
ing type (Type).
When
Parameter
C32=1,
Displays
Stanby
Displays 0.0V
Displays 0A
Displays 0.0m/min
Displays the weld-
ing type (Type).
During welding
During wire inching
Displays the weld-
ing voltage value
(V) that is fed-
back.
Displays the weld-
ing current value
(A) that is fed-
back.
Displays the feed-
ing amount (m/
min) of the motor
that is fed-back, or
the motor current.
(Can be switched
by the parameter
D1-5.)
Displays the weld-
ing type (Type).
During setting param-
eter
Displays the
parameter num-
ber.
Normally displays
"---". When the arc
touch start is
selected, displays
"-" in the parame-
ter P01.
Displays
-P parameter:
ratio (%)
-C parameter:
value
(in decimal)
-D parameter
ON/OFF
Displays the weld-
ing type (Type).
Item
Content
Explanation
g
Power Lamp
Lights when the power supply is turned ON.
h
Warning Lamp
Lights or blinks when an error occurs. The error number is dis-
played on the digital meter.
i
Search Lamp
Lights while the starting point detecting function is used. High
voltage is being generated while the lamp is turned ON. (Effec-
tive only when the starting point detecting unit is installed.)
V
A
Wire m/min
Type
36/129