4.5 List of D Parameters
4-22
HW0480311
HW0480311
*1
To enable the calibration for the external resistance value, the external resistance value
must be measured. For measurement of the external resistance value under your
operation conditions, refer to " 14 Calibration for External Resistance ".
*1
• Always set the parameter "D1-10" to "disabled" (OFF) at times other than data communi-
cations.
• For aluminum welding, it is recommended to set the parameter for the end event "D1- 4"
to "enabled" (ON) since automatic crater processing is effective. The crater processing
requires approx. two seconds after ARCOF instruction. Set additionally the Timer instruc-
tion so that the manipulator stops for two seconds at the welding end point.
• For synergic voltage, the voltage that Yaskawa assumes adequate is specified as 100%.
Changing the synergic voltage by 10%, voltage varies by approx.about 1V. (Example: In
case of 20V at 100%, it becomes 19V and 21V at 90% and 110%, respectively. The per-
centage (%) can be changed in the range between 50% and 150% (±5V).) The percent-
age (%) that is set at robot synergic voltage is displayed on the welding source in the unit
of V.
• For the welding type: CO
2
short-circuit arc welding, do not use the touch start but select
the normal start.
• When aluminum welding is selected, the touch start arc becomes enabled (default set-
D-2
Display
No.
Contents
ON
OFF
Default
Setting
1
External resistance cali-
bration
*1
Compensates by exter-
nal resistance value set
in the parameter C08
Disabled OFF
2
Touch start User File1
Enabled
Disabled (normal start)
OFF
3
Touch start User File2
Enabled
Disabled (normal start)
OFF
4
Touch start User File3
Enabled
Disabled (normal start)
OFF
5
Reserved for system
Do not change.
ON
6
Reserved for system
Do not change.
ON
7
Reserved for system
Do not change.
ON
8
Reserved for system
Do not change.
ON
9
Reserved for system
Do not change.
OFF
10
Reserved for system
Do not change.
OFF
11
Reserved for system
Do not change.
OFF
12
Reserved for system
Do not change.
OFF
13
Reserved for system
Do not change.
ON
14
Reserved for system
Do not change.
ON
15
Error Latch
Error Latch until the
power is turned OFF
Automatic error reset
OFF
16
Reserved for system
Do not change.
OFF
56/129