9.3 Cause and Remedy of Failure at Electrical Circuit Section
9-7
HW0480311
HW0480311
6
Welding voltage (welding voltage
command) cannot be changed
from the robot side.
The analog command sent
from the robot side is not nor-
mal.
Check the analog com-
mand output on the robot
side.
7
Error indication on the digital
meter
See " Table. 5 List of Error
Display Contents ".
See " Table. 5 List of
Error Display Contents ".
8
The power supply switch is
tripped and the power is not
turned ON.
Damage to the input diode
Contact your Yaskawa
representative.
Damage to the main circuit
transistor (IGBT)
9
Shielding gas cannot be adjusted
or stopped.
Failure of the gas solenoid
valve
Investigate the gas sys-
tem.
Fuse (10 A) on the board
Pr(SD)-006 blown
Upon investigating the
error cause, replace the
fuse (10 A) on the printed
board Pr(SD)-006.
Failure of the printed board
(SD)-006
Check or replace the
printed board (SD)-006.
The printed board (SD)-004
is installed by mistake.
(The printed board (SD)-004
cannot be used.)
Replace the board with
the printed board (SD)-
006.
10
The starting point detection can-
not be detected.
The starting point detection
command is not sent to the
welding source or the power
supply for starting point I/F is
not supplied to the welding
source.
Check the connection
signal cable.
The starting point detection
signal is not sent from the
welding source.
Table. 13 Fault Analyses for Electrical Circuit Section
No.
Failure
Cause
Remedy
79/129