14.2.4
Setting the D Parameter for Calibration of External
Resistance to “Enabled"
To validate the calibration for the external resistance, setting using D parameter is required.
1. Display the parameter to set calibration for external resistance as follows:
(1)
With the " Common PRM Select " button pressed, Press the "P.R.M. Select" button.
The D parameter setting display appears.
(2)
Press the “+” button once.”d-2 1” is displayed to set the calibration for the external
resistance to “enabled” or “disabled”.
Fig. 14.2.4.1 Display of D Parameter
Fig. 14.2.4.1 Display of D Parameter
2. Change the parameter setting for calibration of external resistance to “enabled” as follows:
(1)
Press “P.R.M.Set” button twice.
The “OFF” display blinks.
(2)
While the display is blinking, press the “+” button to change the display from “OFF” to
“on”.
When it is “on”, the calibration for the external resistance becomes the valid.
(3)
Press the “P.R.M.Select” button to return to the standby status.
Fig. 14.2.4.2 Setting of D Parameter
Fig. 14.2.4.2 Setting of D Parameter
P.R.M. Select
P.R.M. Set
Weld. Type
Common PRM select
Record
Gas
User File Select
−
File No.1
V
V/Set
AW/S
+
L
R
−
File No.3
-
−
Search
A
Wire m/min
−
Warning
−
Power
−
File No.2
Type
Press the “P.E.M. Select” and “Common
PRM Select” buttons simultaneously to enter
the D parameter setting mode. Then, use
the “+” button to display the parameter D-2
P.R.M. Select
P.R.M. Set
Weld. Type
Common PRM select
Record
Gas
User File Select
−
File No.1
V
V/Set
AW/S
+
L
R
−
File No.3
-
−
Search
A
Wire m/min
−
Warning
−
Power
−
File No.2
Type
After pressing the “P.R.M.
Select” button twice to
make the display “OFF”
blink, press the “+” button
to change the setting of
“d-2 1” setting from “OFF”
to “on”. Pressing the
“P.R.M. Set” button after
changing the setting
returns to the standby
status.