HW0482309
31
The following table explains the display of the meters , , , and .
The content of the display differs according to the status as follows:
Status
Welding
Voltage Indicator
Welding
Current Indicator
Wire Feeding
Speed Indicator
Welding Type
Indicator
During
standby
Displays the set
welding voltage value
(V).
Displays the set
welding current value
(A).
Displays the feeding
amount (m/min) of the
set welding current
value.
Displays the welding
type (Type).
During
welding
During
inching
Displays the welding
voltage value (V) that
is fed-back.
Displays the welding
current value (A) that
is fed-back.
Displays the feeding
amount (m/min) of the
motor that is fed-back,
or the motor current.
(Can be switched by
D-1 parameter 5.)
Displays the welding
type (Type).
During
setting
parameter
Displays the
parameter number.
Normally displays
“---“. When the arc
touch start is selected,
displays “-“
in Parameter P01.
Displays
-P parameter:
ratio (%)
-C parameter
value(in decimal)
-D parameter
ON/OFF
Displays the welding
type (Type).
Display Lamps
Item Content
Explanation
Power Lamp
Lights when the power supply is turned ON.
Warning Lamp
Lights or blinks when an error occurs. The error number is
displayed on the digital meter.
Search Lamp
Lights while the starting point detecting function is used. High
voltage is being generated while the lamp is turned ON. (Effective
only when the starting point detecting unit is installed.)
Setting Buttons
Item
Content
Explanation
Parameter Select
(P parameter)
When this button is pressed during standby status, the display
changes to the P parameter setting display. The indicator No.1
displays “P.00”, and the indicator No.3
displays the parameter set
value. (Effective only when the user file is selected.)
Common Parameter
Select (C parameter)
When this button is pressed during standby status, the display
changes to the common parameter setting display. The indicator
No.1
displays “C.00”, and the indicator No.3
displays the common
parameter set value. Press this button again to return to the
standby display.
Switch of the Remote
Mode and Local Mode
Switches the remote mode and the local mode. The LED indicator
lights in the local mode.
-
Remote mode: Voltage/current command is given by the
operations at the robot side.
-
Local mode: Voltage/current command is given by the
operations on the welder panel.
A
Type
Wire m/min
V