4.5
List of D Parameters
D parameters specify the operation conditions for the welder. Set the parameters according
to the operation conditions.
The D parameters are displayed as follows.
Keep pressing the button No.9 “Common P.R.M. Select” and press the button No.8 "P.R.M.
Select" during standby status.
D-1
Display
No.
Contents ON
OFF
Default
Setting
1
Reserved for system
-
-
OFF
2
Power supply FF
compensation
Enabled Disabled ON
3
Wire slow-down
Enabled
Disabled
ON
4
End event
End condition
processing enabled
Disabled
ON
5
Display of feeding
speed/motor current
Displays feeding
speed
Displays motor
current
ON
6
Reserved for system
-
-
OFF
7
Reserved for system
-
-
ON
8
Reserved for system
-
-
ON
9
Reserved for system
-
-
ON
10
Reserved for system
-
-
ON
11
File switching
Switched at robot
side
Switched on panel
OFF
12
Reserved for system
-
-
OFF
13
Voltage adjustment
Independent
adjustment
Synergic adjustment
OFF
14
Arc length control P
Pulse arc length
control enabled
Disabled
ON
15
Reserved for system
-
-
OFF
16
Reserved for system
-
-
ON