10-30
180788-1CD
HW1484370
10 Maintenance and Inspection
10.4 Notes for Maintenance
MPX2600
10.4
Notes for Maintenance
10.4.1 Encoder Connector (with CAUTION label)
Remove the old battery after connecting the new one so that the encoder
absolute data does not disappear.
10.4.1.1 S-, L-, and U-Axis Motors
The backup connector (crimped contact-pin terminal) is mounted on the
encoder connector of each motor. Refer to
Connection for S-, L-, and U-Axis Motors”
Connection for R-, B-, and T-Axis Motors”
, and connect the battery pack
according to the following procedure.
1. Connect the battery to the connectors for the battery backup of the
motor encoder connector.
2. Confirm all connectors connection after the maintenance check ends,
and then remove the battery pack.
NOTE
Do not remove the battery pack in the connector base.
111 of 116