4-2
157569-1CD
HW0485652
MPL100
4 Wiring
4.2 Cable Connection
Fig. 4-1: Grounding Method
4.2
Cable Connection
Three manipulator cables are delivered with the manipulator: an encoder
cable (1BC) and two power cables (2BC and 3BC). (Refer to
Connect these cables to the manipulator base connectors and to the
DX100. Refer to
Fig. 4-3(a) “Manipulator Cable Connectors (Manipulator
Fig. 4-3(b) “Manipulator Cable Connectors
(Manipulator Side, YR-MPL0100-A04)”
and
Fig. 4-3(c) “Manipulator Cable
4.2.1 Connection to the Manipulator
Before connecting two cables to the manipulator, verify the numbers on
both manipulator cables and the connectors on the connector base of the
manipulator. When connecting, adjust the cable connector positions to
the main key positions of the manipulator, and insert cables in the order of
2BC, 3BC, then 1BC. After inserting the cables, depress the lever until it
clicks.
4.2.2 Connection to the DX100
Before connecting cables to the DX100, verify the numbers on both
manipulator cables and the connectors on the DX100. When connecting,
insert the cables in the order of X21, X22, then X11, and depress each
lever until it clicks.
5.5 mm
2
or more
Bolt M8 (for grounding)
Delivered with the manipulator
Enlarged View A
NOTE
DO NOT cover the cable with heat insulating material, and
avoid multiple cabling.
25 of 106