8.7 Autotuning with a Host Reference
8.7.7 Related Parameters
8-41
8
T
uning
8.7.7
Related Parameters
The following parameters are automatically adjusted or used as reference when you execute
autotuning with a host reference.
Do not change the settings while autotuning with a host reference is being executed.
Yes: The parameter is automatically set.
No: The parameter is not automatically set, but the setting is read during execution.
Parameter
Name
Automatic Changes
Pn100
Speed Loop Gain
Yes
Pn101
Speed Loop Integral Time Constant
Yes
Pn102
Position Loop Gain
Yes
Pn103
Moment of Inertia Ratio
No
Pn121
Friction Compensation Gain
Yes
Pn123
Friction Compensation Coefficient
Yes
Pn124
Friction Compensation Frequency Correction
No
Pn125
Friction Compensation Gain Correction
Yes
Pn401
First Stage First Torque Reference Filter Time Constant
Yes
Pn408
Torque-Related Function Selections
Yes
Pn409
First Stage Notch Filter Frequency
Yes
Pn40A
First Stage Notch Filter Q Value
Yes
Pn40C
Second Stage Notch Filter Frequency
Yes
Pn40D
Second Stage Notch Filter Q Value
Yes
Pn140
Model Following Control-Related Selections
Yes
Pn141
Model Following Control Gain
Yes
Pn142
Model Following Control Gain Correction
Yes
Pn143
Model Following Control Bias in the Forward Direction
Yes
Pn144
Model Following Control Bias in the Reverse Direction
Yes
Pn145
Vibration Suppression 1 Frequency A
Yes
Pn146
Vibration Suppression 1 Frequency B
Yes
Pn147
Model Following Control Speed Feedforward Compensation
Yes
Pn160
Anti-Resonance Control-Related Selections
Yes
Pn161
Anti-Resonance Frequency
Yes
Pn163
Anti-Resonance Damping Gain
Yes