4.2.8 Modified Constants Mode
The modified constants mode is used to change or display user constants that have been changed from their
factory-preset values.
When any user constants have been changed in programming mode (b1-01 through o2-08), press the
DATA/ENTER Key in modified constants mode to display these user constants. (The initialize mode user
constants won’t be displayed.)
Changing Frequency Reference 1 to 30.00 in Modified Constants Mode
In the following example, user constants C1-01 (Acceleration time 1) and d1-01 (Frequency reference 1)
have been changed from their factory settings.
The settings for these two user constants are displayed, and the setting for d1-01 is changed from 60.00 Hz
to 30.00 Hz while C1-01 is set to 20.0 seconds.
Step
Key Sequence
Digital Operator Display
Remarks
1
MENU
MC5
Main Menu
Operation
2
MC5
Main Menu
Modified Consts
3
DATA
ENTER
Accel Time 1
C1
--
01 = 20
.
0 Sec
4
Frequency Ref 1
d1
--
01 = 60
.
00 HZ
5
DATA
ENTER
Frequency Ref 1
060
.
00 HZ
6
RESET
Frequency Ref 1
060
.
00 HZ
Blinking digit moves 1 place to the
right.
7
press 3 times.
Frequency Ref 1
030
.
00HZ
8
DATA
ENTER
Entry Accepted
30.00 Hz is written-in.
Frequency Ref 1
d1
--
01 = 30
.
00 HZ
After a few seconds, the Operator dis-
play is as shown on the left.
9
ESC
MC5
Main Menu
Modified Consts
Preset reference 1 is changed to
30.00 Hz in the modified constants
mode.
10
MENU
MC5
Main Menu
Operation
Returns to the operation mode display.