User Constants
8.2.8 Operator Constants: o
- 32
J
Multi-function Selections: o2
Constant
Name
Setting
Factory
Change
during
Control Methods
Constant
Number
Display
Description
Setting
Range
Factory
Setting
g
during
Opera-
tion
Open Loop
Vector
Flux Vector
Page
o2-01
LOCAL/REMOTE key
enable/disable
Sets the Digital Operator Local/Re-
mote Key
0: Disabled
1
E
bl d (S it h
b t
th
0 1
1
B
B
- 60
o2 01
Local/remote key
1: Enabled (Switches between the
Digital Operator and the
constant settings.)
0 1
1
B
B
60
o2-02
STOP key during
control circuit terminal
operation
Sets the Stop Key in the run mode.
0: Disabled (When the run com-
mand is issued from and exter-
nal terminal, the Stop Key is
disabled )
0 1
1
B
B
- 61
Oper STOP Key
disabled.)
1: Enabled (Effective even during
run.)
o2-03
User constant initial
value
Clears or stores user initial values.
0: Stores/not set
1: Begins storing (Records the set
constants as user initial values.)
2: All clear (Clears all recorded
i iti l
l
)
0 to 2
0
B
B
- 61
o2 03
User Defaults
(
user initial values)
When the set constants are re-
corded as user initial values,
1110 will be displayed in the Ini-
tialize mode (A1-03.)
0 to 2
0
B
B
61
o2-04
kVA selection
Do not set
0 to FF
*
0 *
B
B
61
o2-04
Inverter Model #
Do not set.
0 to FF
*
0 *
B
B
- 61
o2-05
Frequency reference
setting method selec-
tion
When the frequency reference is set
on the Digital Operator frequency
reference monitor, sets whether the
Enter Key is necessary.
0: Enter Key needed
1: Enter Key not needed
0 1
0
A
A
- 61
Operator M.O.P.
1: Enter Key not needed
When set to 1, the Inverter ac-
cepts the frequency reference
without Enter Key operation.
o2-06
Operation selection
when digital operator
is disconnected
Sets the operation when the Digital
Operator is disconnected.
0: Disabled (Operation continues
even if the Digital Operator is
disconnected.)
1
E
bl d (OPR i d t
t d t
0 1
0
A
A
- 63
Oper Detection
1: Enabled (OPR is detected at
Digital Operator disconnection.
Inverter output is cut off, and
fault contact is operated.)
o2-07
Cumulative operation
time setting
Sets the cumulative operation time
in hour units.
Operation time is calculated from
0 to
65535
0
A
A
- 63
o2 07
Elapsed Time Set
Operation time is calculated from
the set values.
65535
0
A
A
63
o2-08
Cumulative operation
time selection
0: Cumulative time when the In-
verter power is on. (All time
while the Inverter power is on is
accumulated.)
0 1
0
A
A
- 63
o2 08
Elapsed Time Run
)
1: Cumulative Inverter run time.
(Only Inverter output time is ac-
cumulated.)
0 1
0
A
A
63
o2-09
Initialize mode selec-
tion
Do not set.
0 to 2
0
A
A
o2 09
Init Mode Sel
Do not set.
0 to 2
0
A
A
*
The factory setting depends upon the Inverter capacity. The values for a 200 V class Inverter of 0.4 kW are given.