5 Installation Procedure
14
YASKAWA ELECTRIC
SIEP C730600 83D YASKAWA AC Drive Option SI-C3 Technical Manual
Procedure A
This section shows the procedure to install and wire the option on a 1000-series drive.
Prepare the Drive for the Option
Before you install the option on a YASKAWA D1000 Series Power Regenerative Converter, make sure that the option
software version is PRG: 0106 or later.
1. Correctly wire the drive as specified by the manual packaged with the drive.
2. Make sure that the drive functions correctly.
for an exploded view of the drive with the option and related components for reference in the
installation procedure.
Figure 6
Figure 6 Drive Components with Option
A – Insertion point for CN5 connector
J – Option modular connector CN1
B – SI-C3 option
K – Drive grounding terminal (FE)
C – Drive front cover
L – Connector CN5-A
D – Keypad
M – Connector CN5-B
(Not available for communication
option installation.)
E – LED label
F – Drive terminal cover
G – Removable tabs for wire routing
N – Connector CN5-C
(Not available for communication
option installation.)
H – Included screws
I – Ground wire
F
H
L
M
N
K
I
B
C
D
E
A
G
L.EER
RD
L.RUN
SD
J