![YASKAWA CC-Link Technical Manual Download Page 57](http://html1.mh-extra.com/html/yaskawa/cc-link/cc-link_technical-manual_3242693057.webp)
10 CC-Link Code Numbers
YASKAWA ELECTRIC
SIEP C730600 83D YASKAWA AC Drive Option SI-C3 Technical Manual
57
130H
(101CH)
CPF contents 1
–
0, 1
Reserved
–
2
A/D conversion error (CPF02)
0083H
3
PWM data error (CPF03)
0084H
4, 5
Reserved
–
6
EEPROM data error (CPF06)
0087H
7
Terminal board communication error (CPF07)
0088H
8
EEPROM serial communication fault (CPF08)
0089H
9, A
Reserved
–
B
RAM fault (CPF11)
008CH
C
Flash memory fault (CPF12)
008DH
D
Watchdog circuit exception (CPF13)
008EH
E
Control circuit fault (CPF14)
008FH
F
Reserved
–
131H
(101DH)
CPF contents 2
–
0
Clock fault (CPF16)
0091H
1
Timing fault (CPF17)
0092H
2
Control circuit fault (CPF18)
0093H
3
Control circuit fault (CPF19)
0094H
4
Hardware fault at power up (CPF20)
0095H
5
Hardware fault at communication start up (CPF21)
0096H
6
A/D conversion fault (CPF22)
0097H
7
Reserved
–
8
Converter capacity signal fault (CPF24)
0099H
9
Terminal board is not properly connected. (CPF25)
009AH
A
ASIC BB circuit error (CPF26)
009BH
B
ASIC PWM setting register error (CPF27)
009CH
C
ASIC PWM pattern error (CPF28)
009DH
D
ASIC on-delay error (CPF29)
009EH
E
ASIC BBON error (CPF30)
009FH
F
ASIC code error (CPF31)
00A0H
132H
(101EH)
CPF contents 3
–
0
ASIC start-up error (CPF32)
00A1H
1
Watch-dog error (CPF33)
00A2H
2
ASIC power/clock error (CPF34)
00A3H
3
External A/D converter error (CPF35)
00A4H
4 to 7
Reserved
–
8
Control circuit error (CPF40)
00A9H
9
Control circuit error (CPF41)
00AAH
A
Control circuit error (CPF42)
00ABH
B
Control circuit error (CPF43)
00ACH
C
Control circuit error (CPF44)
00ADH
D
Control circuit error (CPF45)
00AEH
E, F
Reserved
–
Extended Command
Code
(Monitor Code)
Fault Name
Fault Code (U2, U3)
BIT