RMB/ENERGIE GmbH | 31
Cleaning
Operation manual CHP 5.0 - 30.0 | Status 01.2020
8. Cleaning
D
WARNING!
Risk of burns when cleaning hot system
components!
This chapter contains important information regarding
the correct way to clean the system. The parts of the
system that can become very hot (e.g. flue gas routing)
must not be cleaned while the system is in operation.
A
Read this chapter carefully before cleaning the
system.
A
Do not clean any hot components.
A
Follow the safety instructions.
The system must only be cleaned by qualified users.
D
D
ATTENTION!
Risk of damage caused by cleaning agents!
Sprays, solvents and chlorinated cleaning agents can
cause corrosion and changes in properties.
A
Only use suitable cleaning agents.
At least once a year:
A
Clean the system with a damp cloth.
In the case of heavier soiling:
A
Clean the system with warm water and a neutral,
non-abrasive cleaning agent (domestic washing-up
liquid, pH value 7).
If work that creates considerable dust has being
performed in the installation location
(e.g. drilling, abrasive cutting):
A
First switch off the system.
A
Clean the air filter in the generation unit.
A
Clean the ventilation system in the control cabinet.
When cleaning the MSM filter, refer to the respective
manual.
MSM filter manual.
For questions about cleaning:
A
Contact the manufacturer.