13. Service standards
201
13. Service standards
13.1 Engine tuning
No.
Inspection item
Standard
Limit
Reference
page
1
Intake/exhaust valve clearance
mm
0.15-0.25
-
2.2.2(5)
2
V-belt tension
at 98N (10kgf)
mm
Between alternator
and F.W. pump
Used part
8-10
-
2.2.2(4)
New part
6-8
-
3
Fuel injection pressure
MPa (kgf/cm
2
)
3YM30
11.8-12.8
(120-130)
-
2.2.6(2)
3YM20
12.3-13.28
(125-135)
-
4
Compression pressure (at 250 min
-1
)
MPa (kgf/cm
2
)
3YM30
3.43±0.1
(35±1)
2.75±0.1
(28±1)
3.4
3YM20
3.23±0.1
(33±1)
2.55±0.1
(26±1)
5
Cooling water Capacity
Liter (quart)
Engine
3YM30
4.9 (5.2)
-
2.2.1(5)
3YM20
4.1 (4.3)
-
Coolant recovery tank
0.8 (0.8)
-
6
Lube oil capacity (full)
3YM30 Liter (quart)
(at rake angle 8 degree)
2.8
0
/
-0.2
(3.0)
-
2.2.1.(3)
3YM20 Liter (quart)
(at rake angle 8 degree)
2.7
0
/
-0.2
(2.9)
-
Marine gear KM2P-1
Liter (pint)
0.30 (0.64)
-
7
Lubricating oil pressure
MPa (kgf/cm
2
)
at rated speed
0.29-0.44
(3.0-4.5)
-
-
at low idle speed
0.06(0.6)
or above
-
8.2.5
8
Oil pressure switch operating pressure
MPa (kgf/cm
2
)
0.05±0.01
(0.5±0.1)
-
12.7.1
9
Thermostat
valve opening
temperature
deg. C
69.5-72.5
-
2.5
Full opening lift (mm)
(temperature)
8 or above
(85 deg. C)
-
10
Thermo switch actuating temperature
(deg. C)
ON
93-97
-
2.4.2
12.7.2
Summary of Contents for 3YM20