In the Event of Failure…
Remedy for Trouble
Countermeasure against water leakage error
1. Turn off the earth leakage breaker at left surface of the main unit.
2. After repairing the defective area, wipe water off at the bottom in the unit, and dry thoroughly for
re-starting the operation.
3. If the electrode is removed, make sure to reinstall it.
4. Close the door.
5. Turn on the earth breaker, and press POWER key. Now the defect is repaired, and the unit starts
normal operation.
<How to remove the lower front panel of WG250>
1. Remove the screws at left/right positions of the lower front panel.
2. Pull the panel frontward. Be careful of the cable of the drain switch specially used for water sampling
table.
3. Disconnect the cable of the drain switch for water sampling table. Then, remove the lower front panel.
For installation, perform the above steps in reverse order (from 3 to 1).
Water leakage detection electrode
WG1000