![Yamato WG 1000 Instruction Manual Download Page 45](http://html.mh-extra.com/html/yamato/wg-1000/wg-1000_instruction-manual_905422045.webp)
42
In the Event of Failure…
Failure indication and Its Contents
Alarm Indication Condition
Corrective
measures
Water cutoff alarm
Feed Water Alarm
Check
Flow & Pressure
When raw water pressure
decreases (
<
0.5kg f/cm
2
), or
when water cutoff occurs
Check raw water.
Pretreatment filter
exchange notification
It's time
to exchange
Hollow Filter
When 6 months passed
under continuous energizing
condition
Change the pretreatment
filter.
Press and hold the reset
switch on backside of the
door till a beep is heard.
Then, the alarm indication
is reset.
Ion-exchange resin S
exchange notification
Water Quality NG
It's time
to exchange
Ion-EXCH Resin-S
When the conductivity of
pure water exceeds 1×10
-4
S/m
Change the ion-exchange
resin.
Press and hold the reset
switch on backside of the
door till a beep is heard.
Then, the alarm indication
is reset.
Membrane filter for
distilled water
exchange notification
It's time
to exchange
Distilled Water
Membrane Filter
When 3 months passed
under continuous energizing
condition
Change the membrane
filter for distilled water.
Press and hold the reset
switch on backside of the
door till a beep is heard.
Then, the alarm indication
is reset.
Membrane filter for
pure water exchange
notification
It's time
to exchange
Ion-EXCH Water
Membrane Filter
When 3 months passed
under continuous energizing
condition
Change the membrane
filter for pure water.
Press and hold the reset
switch on backside of the
door till a beep is heard.
Then, the alarm indication
is reset.
Maintenance time
notification
It's time
to maintenance
Service Call
When 3 years passed under
continuous energizing
condition
Perform maintenance of
the unit.
Press and hold the reset
switch on backside of the
door till a beep is heard.
Then, the alarm indication
is reset.