9
2. TECHNICAL SPECIFICATIONS
TECHNICAL DATA
91421
91422
Standard
version
Version with
double load
cap.
Standard
version
Version with
double load
cap.
LOAD CAPACITY
125 Kg
250 Kg
250 Kg
500 Kg
LIFTING HEIGHT
17 m
8,5 m
17 m
8,5 m
LIFTING SPEED
10 m/min
5 m/min
10 m/min
5 m/min
CABLE LENGHT
18 m
18 m
CABLE DIAMETER
3,05 mm
4,2 mm
RESISTER CABLE
> 750 Kg
> 1250 Kg
SERVICE
S3 20% - 10 min
S3 25% - 10 min
MAINS VOLTAGE
230V-50Hz
230V-50Hz
MOTOR PERFORMANCE
500 W
900 W
3. GENERAL SAFETY REGULATION
•
This is a machine for domestic use, this machine cannot be used for the industry.
•
Your sockets must comply with safety rules. In case your sockets are not suitable, they should be
checked by a skilled electrician.
•
The plug of your socket must be earthed and your electric system must have a magneto-thermal
switch and a bipolar overload cut-out system.
•
When the machine is running unwatched, be carefull that children cannot reach it.
•
Do not pull the electric cable to disconnect the plug.
•
The machine shall be protected from frost and low temperatures.
•
In case the machine cannot hoist a load, do not keep pressing the hoisting push button: this
means that the load exceeds the machine maximum capacity.
•
The machine shall not be operated when it is raining or storming.
•
Do not stand under hoisted weights
•
Before starting the work, make sure that the steel cable is correctly winded around the reel and
the pitch is equal to the cable diameter.
•
OBSERVE THE MAXIMUM LOAD INDICATED ON THE HOIST, NOT THAT ON THE HOOK !
•
Don’t lift load bigger then rated load of the hoist.
•
ATTENTION!! NEVER COMPLETELY UNWIND THE THREAD FROM THE REEL AND NEVER WIND THE THREAD
IN THE REVERSE DIRECTION, BECAUSE THIS COULD DAMAGE THE MOTOR STOP RING AND THE REEL.
DAMAGE AND/OR BREAKAGE CAUSED BY THE THREAD BEING WOUND IN THE REVERSE DIRECTION
ARE NOT COVERED BY THE GUARANTEE/WARRANTY, AND WE KEEP US OUT OF ANY RESPONSABILITY
FOR ANY PROBLEM.
•
If the red cable appears do not continue to unroll it.
•
Leave at least three turns of cable around the reel, so that the cable connection is not under
stress.
•
To avoid any danger, do not wind more than 15 mt of cable around the reel.
•
In case the steel cable is worn out, it must be replaced only with a cable of same features
manufactured by us. It can be found at all authorized service shops.
•
Before starting the work, check that switches are in good operating conditions.