8 - 19
–
+
ELEC
EAS00770
CHECKING THE STARTER MOTOR
1. Check:
• commutator
Dirt
→
Clean with 600 grit sandpaper.
2. Measure:
• commutator diameter
a
Out of specification
→
Replace the starter
motor.
3. Measure:
• mica undercut
a
Out of specification
→
Scrape the mica to
the proper measurement with a hacksaw
blade that has been grounded to fit the
commutator.
NOTE:
The mica of the commutator must be undercut
to ensure proper operation of the commutator.
4. Measure:
• armature assembly resistances (commuta-
tor and insulation)
Out of specification
→
Replace the starter
motor.
▼▼▼
▼
▼ ▼▼▼
▼
▼ ▼▼▼
▼
▼ ▼▼▼
▼
▼ ▼▼▼
▼
▼ ▼▼▼
▼
▼▼▼
a. Measure the armature assembly resis-
tances with the pocket tester.
b. If any resistance is out of specification,
replace the starter motor.
▲▲▲
▲
▲ ▲▲▲
▲
▲ ▲▲▲
▲
▲ ▲▲▲
▲
▲ ▲▲▲
▲
▲ ▲▲▲
▲
▲▲▲
Commutator wear limit
27 mm (1.06 in)
Mica undercut
0.7 mm (0.028 in)
Pocket tester
90890-03112
Armature coil
Commutator resistance
1
0.0012 ~ 0.0022
Ω
at 20 °C
(68 °F)
Insulation resistance
2
Above 1 M
Ω
at 20 °C (68 °F)