9-4
E
TRBL
ANLS
SELF-DIAGNOSIS
SELF-DIAGNOSIS
9
DIAGNOSIS CODE INDICATION
9
1. Normal condition
(no defective part or irregular process-
ing is found)
2. Single flash is given every 5 seconds.
a
: Light on, 0.3 second
b
: Light off, 5 seconds
8160
3. Trouble code indication
Example: The illustration indicates code
number 23.
a
: Light on, 0.3 second
b
: Light off, 0.3 second
c
: Light off, 1.7 seconds
d
: Light off, 5 seconds
8170
DIAGNOSIS THE ELECTRONIC
CONTROL SYSTEM
9
1. Install:
• Diagnostic indicator
NOTE:
When performing this diagnosis, all of the
electrical wires must be properly con-
nected.
Diagnostic indicator
YB-06765 / 90890-06765
8150
2. Inspect:
• Diagnosis code
Code 1 is indicated
→
Normal.
Code 13 - 31 indicated
→
Check the
applicable parts.
Code 33 - 44 indicated
→
Replace the
CDI unit.