3-
10
3
I/O INTERF
ACE
3-4 I/O Circuits
3-4
I/O Circuits
This section provides the SRCP controller I/O circuit specifications and examples of how the I/O
circuits should be connected. Refer to these specifications and diagrams when connecting to external
equipment such as a PLC.
3-4-1 I/O circuit specifications
■
Input Power
DC24V
±
10% (supplied through EXT.CN)
■
Input Circuit
Excluding emergency stop input circuit
Insulation method:
Photocoupler insulation
Input terminal:
Relay contact or NPN open collector transistor connected between
input terminal and 0V terminal.
Input response:
30ms max.
Input current:
5mA/DC24V
Input sensitivity:
Current on: 3mA min.
Current off: 1mA max.
Emergency stop input circuit
Input terminal:
Relay contact connected between emergency stop inputs 1 and 2
(between EMG1 and EMG2).
Input response:
5ms max.
Input current:
40mA/DC24V
■
Output Circuit
Insulation method:
Photocoupler insulation between internal circuit and output tran-
sistor
Output terminal:
NPN open collector output of all collective output common termi-
nals (0V side)
Output response:
1ms max.
Max. output current:
50mA/DC24V per output
Residual ON voltage:
1.5V max.
■
Pulse Output Circuit
Output method:
Line driver (26LS31 or equivalent)
Maximum output current: 20mA
Summary of Contents for SRCP
Page 1: ...User s Manual ENGLISH E YAMAHA SINGLE AXIS ROBOT CONTROLLER E84 Ver 2 04 SRCP ...
Page 2: ......
Page 8: ...vi MEMO ...
Page 18: ...1 10 MEMO ...
Page 28: ...2 10 MEMO ...
Page 132: ...8 34 MEMO ...
Page 146: ...9 14 MEMO ...
Page 176: ...10 30 MEMO ...
Page 218: ...12 10 MEMO ...
Page 235: ...15 1 15 SPECIFICATIONS Chapter 15 SPECIFICATIONS ...
Page 240: ...MEMO 15 6 ...
Page 241: ...16 1 16 APPENDIX Chapter 16 APPENDIX ...
Page 245: ...MEMO ...