4 - 80
ENG
CRANKSHAFT AND OIL PUMP
CHECKING THE OIL STRAINER
1. Check:
• oil strainer
Damage
→
Replace.
Contaminants
→
Clean with engine oil.
EBS00360
CHECKING THE CRANKSHAFT
1. Measure:
• crank width
a
Out of specification
→
Replace the crank-
shaft.
2. Measure:
• side clearance
d
Out of specification
→
Replace the crank-
shaft.
3. Measure:
• runout
c
Out of specification
→
Replace the crank-
shaft.
Crank width
74.95 ~ 75.00 mm
(2.951 ~ 2.953 in)
Big end side clearance
0.350 ~ 0.650 mm
(0.0138 ~ 0.0256 in)
<Limit>: 1.0 mm (0.04 in)
Runout limit
0.030 mm (0.0012 in)
a
c
d
c