En
29
Error messages
If any error message is displayed during the measurement, resolve the problem and perform YPAO again. Error message can be confirmed and controlled by viewing both a TV
monitor and the front display.
■
Procedure to exit YPAO
1
Check the contents of error message, and then press ENTER.
2
Press the cursor key ( ) to select “EXIT (Exit)” from the following
choices, and then press ENTER.
Choices: PROCEED (Proceed) (E-5, E-9 only), “RETRY (Retry),” “EXIT (Exit)”
3
Press the cursor key (
) to select “Exit (Exit)” from the following
choices, and then press ENTER.
Choices: Start (Start), Exit (Exit)
4
Remove the YPAO microphone.
■
Cause and remedy for each error message
TV monitor
Front display
STEREO
SLEEP
VOL.
TUNED
PL
PR
SW
C
L
SL
SR
ENHANCER
iPod
CHARGE
R
SW
C
L
SL
SR
R
E-1:NO FRNT SP
YPAO
VOL.
Error message
Cause
Remedy
E-1:No Front SP
(E-1:NO FRNT SP)
Front speakers are not
detected.
Follow “Procedure to exit YPAO” to exit YPAO, turn off the unit, and then check the speaker connections. After removing problems, turn on the unit, and
then perform YPAO again.
E-2:No Sur. SP
(E-2:NO SUR SP)
Either of surround
speakers is not detected.
E-5:Noisy
(E-5:NOISY)
The noise is too loud.
Keep the room quiet and select “RETRY (Retry)” in step 2 of “Procedure to exit YPAO” to restart YPAO for an accurate measurement. Selecting
“PROCEED (Proceed)” allows you to continue measuring, but may not achieve the optimal results.
We recommend selecting “RETRY (Retry)” or “EXIT (Exit)” to retry YPAO again from the beginning.
E-7:No MIC
(E-7:NO MIC)
The YPAO microphone has
been removed.
Connect the YPAO microphone to the YPAO MIC jack firmly and select “RETRY (Retry)” in step 2 of “Procedure to exit YPAO” to restart the measurement.
E-8:No Signal
(E-8:NO SIGNAL)
The YPAO microphone
cannot detect test tones.
Connect the YPAO microphone to the YPAO MIC jack firmly and select “RETRY (Retry)” in step 2 of “Procedure to exit YPAO” to restart the measurement.
If this error occurs repeatedly, contact the nearest authorized Yamaha dealer or service center.
E-9:User Cancel
(E-9:CANCEL)
The measurement has
been canceled.
Select “PROCEED (Proceed)” in step 2 of “Procedure to exit YPAO” to resume the measurement. Select “RETRY (Retry)” to restart the measurement from
first.
E-10:Internal Err.
(E-10:INTERNAL)
An internal error has
occurred.
Follow “Procedure to exit YPAO” to exit YPAO, turn off and on the unit. Perform YPAO again. If this error occurs repeatedly, contact the nearest authorized
Yamaha dealer or service center.
1 2 3 4 5 6 7 8