7-39
COMPONENTES ELÉCTRICOS
VERIFICATION plug cap
1.Check:
• plug cap resistance
OOS
Replace יו.
Resistance of the plug cap
5.0 kU at 20 ° C (68 ° F)
a. Remove the spark plug cap from the spark
plug wire.
b. Connect the multimeter (Ù × 1k) to the spark
plug cap as shown.
Multimeter
c. Measure the resistance of the spark plug cap.
CHECKING THE IGNITION COIL
1.Check:
• Primary coil resistance
OOS
Replace יו.
Primary coil resistance
Ù 0.32 to 0.48 at 20 ° C (68 ° F)
a. Disconnect connectors of the ignition coil, the
terminals of the ignition coil.
b. Connect the multimeter (Ù × 1) to the ignition
coil, as shown.
Multimeter
• Positive tester probe
יו
orange "1"
• Negative tester probe
יו
land "2"
c.
Measure the secondary coil resistance.
2.Check:
• secondary coil resistance
OOS
Replace יו.
Secondary coil resistance
KU 5.68-8.52 at 20 ° C (68 ° F)
a. Disconnect the spark plug cap from the
ignition coil.
b. Connect the multimeter (Ù × 1k) to the ignition
coil, as shown.
Multimeter