Trouble Recovery
99
5. Disconnect the water detection switch
coupler.
NOTICE:
Be careful not to get
any water on the water detection
switch coupler, otherwise a malfunc-
tion could occur.
[ECM01950]
6. Unscrew the filter cup from the filter
housing.
NOTICE:
Be careful not to
twist the water detection switch lead
when unscrewing the filter cup.
[ECM01960]
7. Drain the water in the filter cup by soak-
ing it up with a rag.
8. Firmly screw the filter cup onto the filter
housing.
NOTICE:
Be careful not to
twist the water detection switch lead
when screwing the filter cup onto the
filter housing.
[ECM01970]
9. Connect the water detection switch cou-
pler securely until a click is heard.
10. Fasten the water detection switch lead
with the holder.
1. Holder
1. Water detection switch coupler
1
ZMU07094
1
ZMU07096
1. Filter cup
2. Water detection switch lead
1. Water detection switch coupler
2
1
ZMU07097
1
ZMU07100
6C1-9-26-1E0.book 99 ページ 2010年2月10日 水曜日 午後1時53分