11-
18
11
COMMUNICA
TION WITH PC
11-5 Communication Command Description
(6)@?STP <program number>
Reads the total number of steps in the specified program.
Program number
: This is a number used to identify each program and can be 0 to
99 (a total of 100).
Transmission example
: @?STP 10 c/r l/f ........................... Reads the total number of
steps for program No. 10.
Response example
: 140 c/r l/f
OK c/r l/f
(7)@?MEM
Reads the number of steps that can be added.
Transmission example
: @?MEM c/r l/f
Response example
: 1001 c/r l/f
OK c/r l/f
c
CAUTION
In addition to the number of existing steps, the steps equivalent to the number of programs are used internally as
the program control steps. For example, if one program with 50 steps is registered, the number of the available
remaining steps will be 2949 steps (3000 - 1- 50 = 2949).
(8)@?VER
Reads the ROM version in the ERCX controller.
Transmission example
: @?VER c/r l/f
Response example
: 13.13 c/r l/f
OK c/r l/f
(9)@?ROBOT
Reads the type of the robot currently specified.
Transmission example
: @?ROBOT c/r l/f
Response example
: 90 c/r l/f
OK c/r l/f
(10)@?CLOCK
Reads the total operation time of the ERCX controller.
Transmission example
: @?CLOCK c/r l/f
Response example
: 00101,05:11:12 c/r l/f ................... Indicates that the total opera-
tion time is 101 days, 5 hours,
11 minutes and 12 seconds.
OK c/r l/f
Summary of Contents for ERCX Series
Page 2: ......
Page 8: ...vi MEMO ...
Page 60: ...3 36 MEMO ...
Page 90: ...5 20 MEMO ...
Page 168: ...9 16 MEMO ...
Page 232: ...12 10 MEMO ...
Page 248: ...14 4 MEMO ...
Page 249: ...15 1 15 SPECIFICATIONS Chapter 15 SPECIFICATIONS ...
Page 253: ...16 1 16 APPENDIX Chapter 16 APPENDIX ...
Page 259: ...MEMO ...