10-
11
10
OTHER OPERA
TIONS
10-4 SERVICE mode function
10-4-3 Setting the SERVICE mode functions
1) On the initial screen, press
F3
(SYS).
[MENU]
select menu
1EDIT2OPRT3SYS 4MON
[SYS]
select menu
1SAFE2OPT 3UTL 4next
[SYS-SAFE]
Password: 13.13_
input password
[SYS-SAFE]
select menu
1ACLV2SVCE
[SYS-SAFE-SVCE]
select menu
1SET 2DEV 3SPD 4next
[SYS-SAFE-SVCE-DEV]
data = 0
PB only
2) Press
F4
(next) to change the menu display
and then press
F1
(SAFE).
3) The password request screen appears. Enter the
password and then press
.
4) When the password is correct, the screen shown
on the right appears.
Press
F2
(SVCE) here.
5) Select the item whose setting you want to
change.
To change the setting that limits the operation
device, press
F2
(DEV).
To change the setting that limits the speed, press
F3
(SPD).
To change the setting that limits step operation
and automatic operation, press
F4
(next) and
then press
F1
(RUN).
To change the setting for the hold-to-run func-
tion, press
F4
(next) and then press
F2
(HtoR).
6) The current setting for the selected item ap-
pears.
To change the setting, enter the data with the
number key and then press
.
Summary of Contents for ERCX Series
Page 2: ......
Page 8: ...vi MEMO ...
Page 60: ...3 36 MEMO ...
Page 90: ...5 20 MEMO ...
Page 168: ...9 16 MEMO ...
Page 232: ...12 10 MEMO ...
Page 248: ...14 4 MEMO ...
Page 249: ...15 1 15 SPECIFICATIONS Chapter 15 SPECIFICATIONS ...
Page 253: ...16 1 16 APPENDIX Chapter 16 APPENDIX ...
Page 259: ...MEMO ...