25
3)-4. Key ppp adjust
3)-4-1.Start ppp adjust
3)-5. Calibration – extra
3)-5-1. Sensor manual
3)-5-2. Key drive(0ne key)
3)-5-4. Key drive on, 3)-5-5. Key drive off
3-2.Pedal HP Adjust
3-3.Calibration –
Full
3-4.Key ppp Adjust ↓
[
←→↑↓
]move/adj.[ > ]mode
[SELECT]speed [REC]save
Start
3-4-1.Start ppp Adjust
3-4-2.CLEAR offset data
ENT
[
←→↑↓
]move/adj.[ > ]mode
[SELECT]speed [REC]save
KEY=01 OFFSET=0 ALL
[
←→↑↓
]move/adj.[ > ]mode
[SELECT]speed [REC]save
complete.
3-4-1.Start ppp Adjust
3-4-2.CLEAR offset data
3-4-2.CLEAR offset data
SURE? (PLAY,STOP)
3-3.Calibration –
Full ↑
3-4.Key ppp Adjust
3-5.Calibration - Extra
3-5-1.Sensor Manual
3-5-2.Key Drive(OneKey)
3-5-3.Key Drive ON
ENT
[REC] to save data
MANUAL MEASURE
SNS type : KS
Wait a moment.
Press all key to the end
If finished. Send BF 03
3-5-1.Sensor Manual
3-5-2.Key Drive(OneKey)
3-5-3.Key Drive ON
[+][-]Select key:No01 A
[SELECT]Type:Std
[ENTER] to ‘OK’
[ KD calibration ]
Model : E3 KS
3-5-1.Sensor Manual
3-5-2.Key Drive(OneKey)
3-5-3.Key Drive ON
3-5-2.Key Drive(OneKey)
3-5-3.Key Drive ON
3-5-4.Key Drive OFF
The softest key stroke adjustment is started by enter button.
The buttons works in this adjustment as follows.
[Play/Pause][ENT]: to change mode between all and 1key mode.
[
△
][
▽
] or dial : to change the offset data
[REC]: to save the offset data. [STOP]: to quit the adjustment.
All mode: change the offset data of 88keys all at once. 1key mode: change the offset data of the selected key.
Softest scale is played in the all mode. Only the selected key is played during the 1key
[SELECT]: change the speed of scaling. mode.
[
←
][
→
] cursor: Press the button in the direction of the [
←
][
→
] cursor: moves the selected key one by one.
scaling to move to a scale which is higher or lower by
one octave.
Press the opposite button to change the direction of
scaling.
Clears all the offset data of softest key stroke
adjustment
Sensor manual calibration.
Press down all the keys to end of the stroke.
[REC]: to save the data.
[STOP]: to quit the calibration.
One key calibration.
Select the key to calibrate by [+][-] or dial.
[SELECT]: to change between Std/Full.
[ENT]: to start the calibration.
Calibration to make the key- on table
Calibration to make the key- off table.
3)-4-2. Clear offset data
38