AFC1
23
6.
INSPECTION & ADJUSTMENT
1. After replacing the defective parts, follow the flow chart for
each output voltage system and perform the inspections and
adjustments shown after 2.
2. Check each output voltage without a load and, if necessary,
use the adjustment volume to make fine adjustments.
3. Check each output voltage with the rated load and, if
necessary, use the adjustment volume to make fine
adjustments.
4. The following shows the rated output voltage values,
locations for measuring the output voltage and relevant
volumes for adjustment.
rated output voltage Locations for measuring
Relevant volumes for
values (V)
the output voltage
adjustment
+5V +/-5%
CN5-1pin/CN5-4pin
VR4
+3.3V +/-5%
CN5-3pin/CN5-4pin
VR3
+5V +/-5%
CN2-5pin/CN2-11pin
-
-5V +/-5%
CN2-7pin/CN2-11pin
-
+15V +/-5%
CN2-1pin/CN2-11pin
-
-15V +/-10%
CN2-4pin/CN2-11pin
-
+20V +/-5%
CN2-13pin/CN2-11pin
-
6.
調整・検査
1.不良パーツ交換後、各出力電圧系統のフローチャート
に従って、2 以降の調整・検査を行ないます。
2.無負荷時の各出力電圧を確認し、必要に応じて調整用
ボリュームにて、微調整を行ないます。
3.定格負荷時の各出力電圧を確認し、必要に応じて調整
用ボリュームにて、微調整を行ないます。
4.以下に規定出力電圧値、出力電圧の測定場所及び、該
当する調整用ボリュームを示します。
規定出力電圧値(V)
測定場所
調整用ボリューム
+5V +/-5%
CN5-1pin/CN5-4pin 間
VR4
+3.3V +/-5%
CN5-3pin/CN5-4pin 間
VR3
+5V +/-5%
CN2-5pin/CN2-11pin 間
調整なし
-5V +/-5%
CN2-7pin/CN2-11pin 間
調整なし
+15V +/-5%
CN2-1pin/CN2-11pin 間
調整なし
-15V +/-10%
CN2-4pin/CN2-11pin 間
調整なし
+20V +/-5%
CN2-13pin/CN2-11pin 間