This manual applies to the repair of the switching power
source (V4845900) for AFC1.
1-1. Measuring equipment to be used.
• Oscilloscope
• Digital voltmeter
1-2. Dummy resistance specifications
Connect the dummy load that enables the prescribed
current flow to the specified connector.
Part Code
Output Voltage
Rated Current
Load Resistance
CN5
+5V +/-5%
4A
CN5
+3.3V +/-5%
1A
CN2
+5V +/-5%
0.8A
CN2
-5V +/-5%
0.8A
CN2
+15V +/-5%
0.6A
CN2
-15V +/-10%
0.4A
CN2
+20V +/-5%
0.1A
2.
PROCEDURE (FLOW CHART)
Measure the output voltage of 1 through 7 following. If
the measured values do not satisfy the rated values, follow
the flowchart to identify the defective parts.
1. +3.3V system output voltage (Circuit diagram CN5)
2. +5V system output voltage (Circuit diagram CN5)
3. -15V system output voltage (Circuit diagram CN2)
4. -5V system output voltage (Circuit diagram CN2)
5. +20V system output voltage (Circuit diagram CN2)
6. +15V system output voltage (Circuit diagram CN2)
7. +5V system output voltage (Circuit diagram CN2)
1.
準備
本マニュアルは、
AFC1用スイッチング電源
(V4845900)
の修理に適応します。
1-1. 使用する測定器
・オシロスコープ
・デジタルボルトメータ
1-2. ダミー抵抗の仕様
指定のコネクターに所定の電流を流すダミー負荷を
接続してください。
部品記号
出力電圧
定格電流
負荷抵抗
CN5
+5V +/-5%
4A
CN5
+3.3V +/-5%
1A
CN2
+5V +/-5%
0.8A
CN2
-5V +/-5%
0.8A
CN2
+15V +/-5%
0.6A
CN2
-15V +/-10%
0.4A
CN2
+20V +/-5%
0.1A
2.
手順(フローチャート)
次頁 1 〜 7 の出力電圧を測定し、測定値が規定値を
満たさない場合、フローチャートに従って、不具合
部品を特定化します。
1.+3.3V 系出力電圧(回路図 CN5)
2.+5V 系出力電圧(回路図 CN5)
3.-15V 系出力電圧(回路図 CN2)
4.-5V 系出力電圧(回路図 CN2)
5.+20V 系出力電圧(回路図 CN2)
6.+15V 系出力電圧(回路図 CN2)
7.+5V 系出力電圧(回路図 CN2)