AFC1
17
3.
WAVE FORM SAMPLE
(出力波形)
Sample waveforms that have been referred to in the flow chart are shown after the following page.
(フローチャートで引用されているサンプル波形を示します。)
(波形測定:回路図
2/2 “Point G”
波形サンプル
fig.3
)
(波形測定:回路図
1/2 “Point D”
波形サンプル
fig.2
)
(
*1:
実際には83 KHzにて動作。測定器都合上167.5 KHzに表示)
(波形測定:回路図
1/2 “Point B”
波形サンプル
fig.1
)
FREQUENCY:
ON DUTY:
83.41KHz
33.6%
*1
FREQUENCY:
ON DUTY:
167.5KHz
38.3%
FREQUENCY:
ON DUTY:
83.51KHz
51.0%
Wave form measurement: Circuit Drawing 1/2 “Point B”
(Wave form sample. fig.1)
Wave form measurement: Circuit Drawing 1/2 “Point D”
(Wave form sample. fig.2)
*1: Operation is actually at 83 KHz. However, measuring unit will
display 167.5 KHz.
Wave form measurement: Circuit Drawing 2/2 “Point G”
(Wave form sample. fig.3)
(周波数)
(周波数)
(周波数)
Ch1
100V
M 2.5 s
Ch1
Ch1 Freq
83.41kHz
Ch1 +Duty
33.6%
2431 Acqs
Tek
Stop:
20MS/s
372V
1
T
Ch1
5V
M 2.5 s
Ch1
Ch1 Freq
167.5kHz
Ch1 +Duty
38.3%
181 Acqs
Tek
Stop:
20MS/s
17.6V
1
T
Ch1
10V
M 2.5 s
Ch1
Ch1 Freq
83.51kHz
Ch1 +Duty
51%
410 Acqs
Tek
Stop:
20MS/s
800mV
1
T
400V
18V
3.0
9.0
24V
24V
6.0