9-18
CHARGING SYSTEM
–
+
ELEC
EBS01066
NO
YES
EBS01100
YES
NO
3. Charging voltage
• Connect the engine tachometer to the
spark plug lead.
• Connect the pocket tester (DC 20 V) to the
battery as shown.
Positive tester probe
→
positive battery terminal
Negative tester probe
→
negative battery terminal
• Start the engine and let it run at approxi-
mately 5,000 r/min.
• Measure the charging voltage.
Charging voltage
14 V at 5,000 r/min
TIP
Make sure the battery is fully charged.
• Is the charging voltage within specifica-
tion?
The charging circuit
is OK.
4. Charging coil resistance
• Disconnect the C.D.I. magneto coupler
from the wire harness.
• Connect the pocket tester (
Ω×
1) to the
charging coils.
Positive tester probe
→
yellow terminal
Negative tester probe
→
yellow terminal
• Measure the charging coil resistance.
Charging coil resistance
0.20 ~ 0.40
Ω
at 20 °C (68 °F)
(between yellow and yellow)
Replace the rectifier/
regulator.
Replace the pickup
coil/stator assembly.
Positive tester probe
→
yellow terminal
Negative tester probe
→
yellow terminal
DC20V
1
2
3
2
3
Y
Y
Y
Ω×
1
YES
NO
5.Wiring
• Check the entire charging system’s wiring.
Refer to “CIRCUIT DIAGRAM”.
• Is the charging system’s wiring properly
connected and without defects?
Replace the rectifier/
regulator.
Replace the diode
and properly con-
nect or repair the
charging
system’s
wiring.