    Resetting Lock to Factory Default

Reset Button

Interior Escutcheon

FCC:

Class B Equipment 

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC 
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This 
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the 
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not 
occur in a particular installation. If this equipment does cause harmful Interference to radio or television reception, which can be 
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the 
following measures:

 Reorient or relocate the receiving antenna.

 Increase the separation between the equipment and receiver.

 Connect the equipment into an outlet on a circuit different from that to which the  receiver is connected.

 Consult the dealer or an experienced radio/TV technician for help.

Industry Canada:

This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. 
Cet appareillage numérique de la classe A répond à toutes les exigences de l'interférence canadienne causant des règlements 
d'équipement. 

Warning: 

Changes or modifications to this device, not expressly approved by 

Yale Security Inc.

 could void the user's authority to 

operate the equipment.

When lock is reset to factory defaults all user codes 
(including the Master PIN code*) are deleted and all 
programming features are reset to original default 
settings (see below).

1. Remove the battery cover and batteries.
2. Remove the interior escutcheon to access the 

reset button.

3. The reset button (see image at right) is located 

above the PCB cable connector.

4. While pressing the reset button (minimum of 3 

seconds) reinstall batteries. Release reset button.

5. Replace battery cover.

Upon reset, Master PIN Code creation is the only 
option available and must be performed prior to any 
other programming of the lock.

Summary of Contents for Real Living YAYRL220ZWx

Page 1: ...hine screws x2 7 wood 8 32 machine x 20mm Combination screws x4 M4 x 8mm pan head machine screws x4 FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN DAMAGE TO THE PRODUCT AND VOID THE FACTORY WARRANTY Yale Real Living Touchscreen Lever Installation and Programming Instructions ...

Page 2: ...2 P N AYRL 220 INST FUL Rev D 2 Phillips Screwdriver 2 3 8 through bolt posts 2 3 4 through bolt posts Note Adjustment based on backset O optional default Preparing to Install ...

Page 3: ...Left Open Inward LH Left Hand Reverse Hinges Left Open Outward LHR The hand of a door is determined from the secure side of the door The term secure means the side from which you initially unlock and enter Determining Lever Handing Left Hand Options ...

Page 4: ...s determined from the secure side of the door The term secure means the side from which you initially unlock and enter Right Hand Hinges Right Open Inward RH Right Hand Reverse Hinges Right Open Outward RHR Determining Lever Handing Right Hand Options ...

Page 5: ...5 P N AYRL 220 INST FUL Rev D x4 1 Installing Latch Strike Plate Left Hand Installation Shown Outside of Door Outside of Door Frame Frame ...

Page 6: ...6 P N AYRL 220 INST FUL Rev D 2 Inside of Left Hand Door Outside of Left Hand Door Do not remove clip until Step 6 Installing Exterior Escutcheon Left Hand Installation Shown ...

Page 7: ... P N AYRL 220 INST FUL Rev D x2 3 Inside of Left Hand Door Outside of Left Hand Door Inside of Left Hand Door Loosen screw to remove cover Installing Interior Mounting Plate Left Hand Installation Shown ...

Page 8: ...4 Inside of Left Hand Door Inside of Left Hand Door Attaching the Cable Assembly Left Hand Installation Shown 8 P N AYRL 220 INST FUL Rev D ...

Page 9: ...9 P N AYRL 220 INST FUL Rev D x4 5 Inside of Left Hand Door Installing Interior Escutcheon Left Hand Installation Shown ...

Page 10: ...ove clip Do not rotate internal cam marked red Red mark must remain on top and in position Outside of Left Hand Door Outside of Left Hand Door Do Not Overtighten Do Not Turn Counter Clockwise Do Not Overtighten Do Not Turn Counter Clockwise Outside of Right Hand Door ...

Page 11: ...11 P N AYRL 220 INST FUL Rev D 6 Installing Exterior Lever con t Outside of Left Hand Door Outside of Right Hand Door ...

Page 12: ...P N AYRL 220 INST FUL Rev D 6 Installing Exterior Lever con t Outside of Left hand Door Outside of Left Hand Door Do Not Overtighten Outside of Right Hand Door Do Not Overtighten Outside of Right Hand Door ...

Page 13: ...220 INST FUL Rev D 7 6 7 6 Testing Operation Inside of Door Outside of Left Hand Door Outside of Right Hand Door Outside of Left Hand Door Outside of Right Hand Door Left Hand Door Shown Right Hand Door Shown OR OR ...

Page 14: ...Door Inside of Right Hand Door Do Not Overtighten Do Not Overtighten Inside of Left Hand Door Inside of Right Hand Door Almost done Turn sheet over to finish installation and customize your product with Programming Instructions Installing Interior Lever x1 ...

Page 15: ...15 P N AYRL 220 INST FUL Rev D 7 Installing Interior Lever con t Inside of Left Hand Door Inside of Right Hand Door Do Not Overtighten Do Not Overtighten ...

Page 16: ...16 P N AYRL 220 INST FUL Rev D Inside of Door 7 Testing Final Operation Outside of Left Hand Door ...

Page 17: ...17 P N AYRL 220 INST FUL Rev D Testing Final Operation Inside of Left Hand Door 7 Inside of Door Inside of Door ...

Page 18: ...18 P N AYRL 220 INST FUL Rev D Inside of Door 7 Testing Final Operation Outside of Left Hand Door ...

Page 19: ...ide of Left Hand Door Installing Batteries Cover 9 Congratulations you ve installed the Yale Real Living Touchscreen Lever Continue with Programming Instructions to customize your product Inside of Left Hand Door Welcome to Yale Real Living Tighten screw to replace cover ...

Page 20: ...iver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Industry Canada This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareillage numérique de la classe A répond à toutes les exigences de l interférence canad...

Page 21: ...e Product Support Tel 800 810 WIRE 9473 www yalelocks com Yale Locks Hardware is a division of Yale Security Inc an ASSA ABLOY Group company YALE with its unique global reach and range of products is the world s favorite lock the preferred solution for securing your home family and personal belongings Latch will not deadlock a Check for sufficient clearance of the latch within the strike side jamb ...

Page 22: ...y default Programming and use of lock is not possible until this step has been successfully completed Max User Codes 250 with Network Module Max User Codes 25 without P Key Return to Previous Low Battery Indicator Lockout Mode Speaker Lock Activation Programming Instructions 22 P N AYRL 220 INST FUL Rev D ...

Page 23: ...e lock to factory default Programming and use of lock is not possible until this step has been successfully completed Enter 4 8 digit Master PIN Code Press Press Register Master Code Press the pound key to continue Enter a 4 to 8 digit PIN code followed by the pound key Registered 23 P N AYRL 220 INST FUL Rev D ...

Page 24: ...s 25 without Enter Master PIN code Press Press Press Press Press Press Enter User number 1 25 or 1 250 Press Adding more User Codes Enter 4 8 digit PIN code Press To end programming Enter 4 8 digit PIN code Press code flashes Press Menu Mode enter number press the pound key to continue 24 P N AYRL 220 INST FUL Rev D ...

Page 25: ...ry Settings Settings Factory Setting Master PIN Code Automatic Re lock Disabled Volume Setting Enabled Low Automatic Re lock Time 30 Seconds Shutdown Time 60 Seconds The Master PIN code must be registered prior to any other programming of the lock Code Chart Duplicate if necessary PIN Code Management With Network Module Up to 250 Users Master User ___ User ___ User ___ User Name User Type PIN Code...

Page 26: ...ional Network Module installed this setting becomes available thru the Main Menu 7 and allows the lock to connect with a network controller One Touch Locking When the latch is retracted activating the keypad will extend the latch during Automatic Re lock duration or when Automatic Re lock is disabled When One Touch Re lock is not in use disabled any valid PIN code will re lock the lock Previous Wh...

Page 27: ...IN code must be registered prior to any other programming of the lock Master PIN Code Setting M User PIN Code Registration Register Delete Advanced Lock Settings Volume Setting Language Setting mode Lockout Mode Network Module Setting Join the network Enable Disable Exit the network User Number UN 1 25 without network module 1 250 with network module U This function appears only with RF network mo...

Page 28: ... pound cannot be used as part of the PIN code Upon entering a PIN code and pressing key the unit displays invalid code error or lock times out with out responding Lockout Mode is enabled Only the Master can enable disable Lockout Mode Contact the Master user Upon entering a PIN code and pressing the key the red padlock icon appears and there are different tones Check to see if the lock is set to L...