26
P/N AYRL-220-INST-FUL Rev D
Definitions
All Code Lockout Mode:
This feature is enabled by the Master code. When enabled, it restricts all user (except
Master) PIN code access. When attempting to enter a code while the unit is in Lockout, the RED locked padlock
will appear on the screen.
Automatic Re-lock Time:
After a successful code entry and the unit unlocks, it will automatically re-lock after
thirty (30) seconds.
Inside Indicator Light:
Located on the interior escutcheon. Shows active status (Locked) of lock and can be
enabled or disabled in the
Advanced Lock Settings
(Main Menu selection #3).
Language Setting Mode:
Choosing English (1), Spanish (2) or French (3) becomes the (default) setting for the
lock's voice prompts.
Low Battery:
When battery power is low, the Low Battery Warning indicator flashes RED. If battery power is
completely lost, use the cylinder key override.
Master PIN Code:
The Master PIN code is used for programming and for feature settings.
It
must be created
prior to programming the lock.
The Master code will also operate (unlock/lock) the lock.
Network Module Setting:
With the optional Network Module installed, this setting becomes available thru the
Main Menu (7) and allows the lock to connect with a network controller.
One Touch Locking:
When the latch is retracted, activating the keypad will extend the latch (during Automatic Re-
lock duration or when Automatic Re-lock is disabled). When One-Touch Re-lock is
not
in use
(disabled),
any
valid PIN code will re-lock the lock.
Previous:
While in Menu Mode, pressing this icon cancels the current operation and returns the user to the
previous step.
Shutdown Time:
The unit will shutdown (flashing RED) for sixty (60) seconds and not allow operation after the
wrong code entry limit (5 attempts) has been met.
Tamper Alert:
Audible alarm sounds if attempting to forcibly remove outside lock from door.
User PIN Code:
The User code operates the lock. Maximum number of user codes is 250 with Network Module;
without Network Module, maximum is 25 users codes. Note: When deleting User PIN code(s), screen will display
User Number (not PIN code) being deleted.
Volume Setting Mode:
The volume setting for PIN code verification is set to
Low (2)
by default; otherwise it can
be set to
High (1)
or
Silent (3)
for quiet areas.
Wrong Code Entry Limit:
After five (5) unsuccessful attempts at entering a valid PIN code, the unit will shut down
and not allow operation.