3.
Is the Power On LED illuminated continuously
when the charger is connected to a 120 volt AC
power source?
a. YES:
b. NO:
Replace the charger.
4.
Is the Detection LED illuminated continuously
when the charger is connected to a 120 volt AC
power source?
a. YES:
Battery is not connected to charger or
battery voltage is less than 2V. Check connec-
tions. If connections are clean and tight, trou-
bleshoot the battery pack. See Battery Pack
Troubleshooting.
b. NO:
5.
Is the Charging LED either flashing or illuminated
continuously when the charger is connected to a
120 volt AC power source?
a. YES:
b. NO:
If no other LEDs are flashing, replace
charger.
6.
Check the output of the charger using a digital
voltmeter:
a.
Connect the voltmeter to the charger's positive
(Red) and negative (Black) connections at the
battery terminals. Record the voltage and then
monitor it for approximately 3 minutes. Did the
voltage
INCREASE
while monitoring?
(1) YES:
The charger is functioning correctly.
Proceed to Step 7.
(2) NO:
Replace the charger.
7.
Was the voltage reading in Step 6 higher than
16VDC?
a. YES:
Proceed to Battery Pack Troubleshoot-
ing.
b. NO:
It is recommended that all batteries in the
battery pack be replaced.
Error Modes
The three red LEDs are used to troubleshoot the
charger. Observe the operation of the Power On, Ab-
normal Shutdown, and the Detection Error LEDs to
determine the cause for the error notification. See Ta-
ble 9.
Table 9. LED Error Codes
CONDITION
LED 1
LED 2
LED 3
LED 4
LED 5
Battery Voltage High
Off
Off
Off
Off
Flash
Battery Pack Unbalanced
Off
Off
Flash
Off
Off
Excessive Charging Time
Off
Off
Flash
Flash
Flash
Battery Testing - 1
Off
Flash
Off
Off
Flash
Battery Testing - 2
Off
Flash
Off
Flash
Off
Inhibit Control Defective
Off
Flash
Off
Flash
Flash
Internal Over Temperature
Off
Flash
Flash
Off
Flash
Mode Selected Not Valid
Flash
Off
Off
Flash
Off
Database Save Error
Flash
Off
Off
Flash
Flash
Discharge Error
Flash
Flash
Off
Off
Off
Severe Discharge Error
Flash
Flash
Flash
Off
Off
Battery Storage Error
Flash
Off
Flash
Off
Flash
Critical Battery Error
On
On
Off
Off
Off
2200 YRM 1007
Battery Charger (Accusense
®
20A)
51
Summary of Contents for MPB040-E
Page 4: ......
Page 10: ...Hydraulic Pump 1900 YRM 1018 Figure 4 Hydraulic Unit 6 ...
Page 19: ......
Page 65: ...Figure 30 Switch Position Mode Chart 2200 YRM 1007 Battery Charger Accusense by DPI 41 ...
Page 79: ......
Page 80: ...2200 YRM 1007 10 16 8 16 1 14 9 13 12 12 7 11 ...
Page 84: ......
Page 93: ......
Page 95: ...Maintenance DC MOTOR MAINTENANCE ALL ELECTRIC LIFT TRUCKS PART NO 524158039 0620 YRM 0294 ...
Page 98: ......
Page 128: ...NOTES 30 ...
Page 129: ......