Table 4. Battery Chart for DPI Gen III Chargers Only
Mfg
Part
Voltage
Capacity
20HR/
RC@25A
(AmpHrs)
Application
Batt Type
DPI Gen III
Mode
US - Battery
Lead Acid
Batteries
US1800
24
208
Deep Cycle
HV Flooded
2
AGM2224
24
224
Deep Cycle
Absorbent Glass
Mat
4
Changing Mode Setting (DPI Accusense Gen
III Models with Jumper Ports)
NOTE:
Mode settings can be checked by connecting
the battery charger to a 120V AC power source and
watching the LED display. The LED display will flash
once if the mode is set to Mode 1, twice if set to Mode
2, three times if set to Mode 3, and four times if the
charger is set to Mode 4. If the LEDs do not flash
when initially connected to power, refer to Trouble-
shooting (DPI Chargers) in this section.
Modes are set by the position of the jumpers on the
jumper port. Accessing the jumper port requires re-
moval of a plate on the front of the battery charger on
DPI Gen III chargers.
1.
Remove the screws used to retain the jumper port
cover to the charger and remove the cover.
2.
Locate the jumpers on the port.
3.
Arrange the jumpers in the proper configuration
for your battery type.
4.
Replace the cover on the charger and install the
mounting screws.
Accusense Gen III with Dip Switches
Battery Charger (Accusense by DPI
®
)
2200 YRM 1007
40
Summary of Contents for MPB040-E
Page 4: ......
Page 10: ...Hydraulic Pump 1900 YRM 1018 Figure 4 Hydraulic Unit 6 ...
Page 19: ......
Page 65: ...Figure 30 Switch Position Mode Chart 2200 YRM 1007 Battery Charger Accusense by DPI 41 ...
Page 79: ......
Page 80: ...2200 YRM 1007 10 16 8 16 1 14 9 13 12 12 7 11 ...
Page 84: ......
Page 93: ......
Page 95: ...Maintenance DC MOTOR MAINTENANCE ALL ELECTRIC LIFT TRUCKS PART NO 524158039 0620 YRM 0294 ...
Page 98: ......
Page 128: ...NOTES 30 ...
Page 129: ......