![Yale MPB040-E Manual Download Page 105](http://html1.mh-extra.com/html/yale/mpb040-e/mpb040-e_manual_3124464105.webp)
Table 2. Commutator Problems (Continued)
Problem
Possible Cause
Illustration
Grooves that are the
width of the brushes.
•
Operation of the
motor in dirty and
abrasive condi-
tions.
•
Wrong type of
brushes for this
motor and opera-
tion.
•
Brush pressure is
too high.
A condition called copper
drag occurs when copper
from the commutator bar
is pulled into the slot be-
tween the commutator
bars. This condition will
cause a short circuit be-
tween the commutator
bars if it is not corrected.
The brushes will wear
rapidly.
•
Operation of the
motor in dirty and
abrasive condi-
tions.
•
Brush holder is not
adjusted electri-
cally correct for the
motor.
•
Wrong type of
brushes for this
motor and opera-
tion.
•
Brush pressure is
wrong (too high or
too low).
0620 YRM 0294
Brush and Commutator Inspection
7